SILVESTRI, SERGIO

SILVESTRI, SERGIO  

Facoltà Dipartimentale di Ingegneria  

Mostra records
Risultati 1 - 20 di 186 (tempo di esecuzione: 0.032 secondi).
Titolo Data di pubblicazione Autore(i) File
A Flexible Control and Analysis Tool for Automatic Blood Pressure Measurement 1-gen-2005 Silvestri, S; G., Savoja
A high sensitivity fiber optic macro-bend based gas flow rate transducer for low flow rates: Theory, working principle, and static calibration 1-gen-2013 Schena, E; Saccomandi, P; Silvestri, S
A Micro Opto-Mechanical Displacement Sensor Based on Micro-Diffraction Gratings: Design and Characterization 1-gen-2013 Accoto, D; Schena, E; Cidda, M; Francomano, M; Saccomandi, P; Silvestri, S
A micromachined intensity-modulated fiber optic sensor for strain measurements: Working principle and static calibration 1-gen-2012 Moscato, M; Schena, E; Saccomandi, P; Francomano, Mt; Accoto, D; Guglielmelli, E; Silvestri, S
A morphing technique to estimate lung cancer deformation due to breathing in radiotherapic treatment 1-gen-2010 Masselli, G. M. P.; Battista, L; Silvestri, S; Ramella, S; Trodella, L
A needlelike probe for temperature monitoring during laser ablation based on FBG: manufacturing and characterization 1-gen-2015 Polito, D; Caponero, M A; Polimadei, A; Saccomandi, P; Massaroni, C; Silvestri, S; Schena, E
A new methodology for intra-breath control of mechanical ventilation 1-gen-2012 Cecchini, S; Sardellitti, I; Silvestri, S
A novel control strategy to improve performances of heated wire humidifiers in artificial neonatal ventilation 1-gen-2012 Schena, E; Saccomandi, P; Ramandi, C; Silvestri, S
A novel device to simulate low respiratory static compliances of pre-term infants measuring expansion tidal volume 1-gen-2003 Sardellitti, I.; Silvestri, S; Cappa, P.
A Novel Method to Compute Breathing Volumes via Motion Capture Systems: Design and Experimental Trials 1-gen-2017 Massaroni, C; Cassetta, E; Silvestri, S
A novel methodology for the experimental evaluation of pulmonary ventilator performance drift 1-gen-1997 Branca, Fp; Cappa, P; Sciuto, Sa; Silvestri, S
A novel preterm respiratory mechanics active simulator to test the performances of neonatal pulmonary ventilators 1-gen-2002 Cappa, P; Sciuto, Sa; Silvestri, S
A novel target type low pressure-drop bidirectional optoelectronic air flow sensor for infant artificial ventilation: measurement principle and static calibration 1-gen-2011 Saccomandi, P; Schena, E; Silvestri, S
A Novel Tool and Procedure for In-Situ Volumetric Calibration of Motion Capture Systems for Breathing Analysis 1-gen-2016 Massaroni, C; Schena, E; Saccomandi, P; Silvestri, S
A preliminary efficacy evaluation performed by opto-electronic plethysmography of asymmetric respiratory rehabilitation 1-gen-2009 Bastianini, F.; Silvestri, S; Magrone, G.; Gallotta, E.; Sterzi, S.
A reliability analysis of non parametric tests for combined cyclic and monotonous drift evaluation 1-gen-2000 Silvestri, S; Cappa, P; Sciuto, Sa
A reliability analysis of non parametric tests for drift evaluation 1-gen-1999 Cappa, P; Sciuto, Sa; Silvestri, S
A Review on Methods and Devices for Force Platforms Calibration in Medical Applications 1-gen-2018 Scorza, A; Massaroni, C; Orsini, F; D’Anna, C; Conforto, S; Silvestri, S; Sciuto, S A
A standard methodology to evaluate contrast resolution of ultrasound medical imaging devices 1-gen-2008 Masselli, G. M. P.; Silvestri, S
A Standard Protocol Proposal for Reliable and Time-Saving Shielding Effectiveness Measurements for MRI Faraday Cages 1-gen-2020 Mirarchi, L; Giaquinto, V; Silvestri, S; Massa, R