This study introduced a 3D-printed sensing element based on fiber Bragg grating (FBG) technology to measure grasping forces when integrated into surgical forceps during minimally invasive surgery (MIS). Its design mainly consists of an octagonal-shaped structure with a single FBG suspended within, the first to use fused deposition modeling technique in this application scenario. This novel solution allows improving the design customization and the structural robustness of the proposed sensing element. A finite element model was developed to study the mechanical behavior of the structure under transversal force (F) values experienced during grasping. Thermoplastic polyurethane material as printing filament enhanced the deformation capabilities of the sensor, thereby optimizing its response to F as evidenced by the value of sensitivity to F (i.e., 0.11 nm·N−1). Additionally, the sensing element exhibited a low hysteresis error (always below 14 %). Tests in controlled conditions confirmed...

A 3D-printed sensing element based on fiber Bragg grating technology for grasping force measurement in surgical forceps

De Tommasi F.;Massaroni C.;Gizzi A.;Silvestri S.;Schena E.;Lo Presti D.
2025-01-01

Abstract

This study introduced a 3D-printed sensing element based on fiber Bragg grating (FBG) technology to measure grasping forces when integrated into surgical forceps during minimally invasive surgery (MIS). Its design mainly consists of an octagonal-shaped structure with a single FBG suspended within, the first to use fused deposition modeling technique in this application scenario. This novel solution allows improving the design customization and the structural robustness of the proposed sensing element. A finite element model was developed to study the mechanical behavior of the structure under transversal force (F) values experienced during grasping. Thermoplastic polyurethane material as printing filament enhanced the deformation capabilities of the sensor, thereby optimizing its response to F as evidenced by the value of sensitivity to F (i.e., 0.11 nm·N−1). Additionally, the sensing element exhibited a low hysteresis error (always below 14 %). Tests in controlled conditions confirmed...
2025
Additive manufacturing; Fiber Bragg grating sensors; Force feedback; Force measurements; Minimally invasive surgery;
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12610/87683
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact