BACKGROUND Current guidelines recommend at least 24 hours of electrocardiographic (ECG) monitoring after an ischemic stroke to rule out atrial fibrillation. However, the most effective duration and type of monitoring have not been established, and the cause of ischemic stroke remains uncertain despite a complete diagnostic evaluation in 20 to 40% of cases (cryptogenic stroke). Detection of atrial fibrillation after cryptogenic stroke has therapeutic implications. METHODS We conducted a randomized, controlled study of 441 patients to assess whether long-term monitoring with an insertable cardiac monitor (ICM) is more effective than conventional follow-up (control) for detecting atrial fibrillation in patients with cryptogenic stroke. Patients 40 years of age or older with no evidence of atrial fibrillation during at least 24 hours of ECG monitoring underwent randomization within 90 days after the index event. The primary end point was the time to first detection of atrial fibrillation (lasting >30 seconds) within 6 months. Among the secondary end points was the time to first detection of atrial fibrillation within 12 months. Data were analyzed according to the intention-to-treat principle. RESULTS By 6 months, atrial fibrillation had been detected in 8.9% of patients in the ICM group (19 patients) versus 1.4% of patients in the control group (3 patients) (hazard ratio, 6.4; 95% confidence interval [CI], 1.9 to 21.7; P<0.001). By 12 months, atrial fib-rillation had been detected in 12.4% of patients in the ICM group (29 patients) versus 2.0% of patients in the control group (4 patients) (hazard ratio, 7.3; 95% CI, 2.6 to 20.8; P<0.001). CONCLUSIONS ECG monitoring with an ICM was superior to conventional follow-up for detecting atrial fibrillation after cryptogenic stroke.

Cryptogenic Stroke and Underlying Atrial Fibrillation

Di Lazzaro V;
2014-01-01

Abstract

BACKGROUND Current guidelines recommend at least 24 hours of electrocardiographic (ECG) monitoring after an ischemic stroke to rule out atrial fibrillation. However, the most effective duration and type of monitoring have not been established, and the cause of ischemic stroke remains uncertain despite a complete diagnostic evaluation in 20 to 40% of cases (cryptogenic stroke). Detection of atrial fibrillation after cryptogenic stroke has therapeutic implications. METHODS We conducted a randomized, controlled study of 441 patients to assess whether long-term monitoring with an insertable cardiac monitor (ICM) is more effective than conventional follow-up (control) for detecting atrial fibrillation in patients with cryptogenic stroke. Patients 40 years of age or older with no evidence of atrial fibrillation during at least 24 hours of ECG monitoring underwent randomization within 90 days after the index event. The primary end point was the time to first detection of atrial fibrillation (lasting >30 seconds) within 6 months. Among the secondary end points was the time to first detection of atrial fibrillation within 12 months. Data were analyzed according to the intention-to-treat principle. RESULTS By 6 months, atrial fibrillation had been detected in 8.9% of patients in the ICM group (19 patients) versus 1.4% of patients in the control group (3 patients) (hazard ratio, 6.4; 95% confidence interval [CI], 1.9 to 21.7; P<0.001). By 12 months, atrial fib-rillation had been detected in 12.4% of patients in the ICM group (29 patients) versus 2.0% of patients in the control group (4 patients) (hazard ratio, 7.3; 95% CI, 2.6 to 20.8; P<0.001). CONCLUSIONS ECG monitoring with an ICM was superior to conventional follow-up for detecting atrial fibrillation after cryptogenic stroke.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12610/10931
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1567
  • ???jsp.display-item.citation.isi??? 1410
social impact