: Background: The natural history of tricuspid valve regurgitation (TR) is characterized by poor prognosis and high in-hospital mortality when treated with isolated surgery. We report the preliminary echocardiographic and procedural results of a prospective cohort of symptomatic patients with high to prohibitive surgical risk and at least severe TR who underwent transcatheter edge-to-edge repair through the TriClipTM system. Methods: From June 2020 to March 2022, 27 consecutive patients were screened, and 13 underwent transcatheter TriClipTM repair. In-hospital, 30-day and six-month clinical and echocardiographic outcomes were collected. Results: Nine patients had severe, three massive and one baseline torrential TR. Sustained TR reduction of ≥1 grade was achieved in all patients, of which 90% reached a moderate TR or less. On transthoracic echocardiographic examination, there were significant reductions in vena contracta width (p < 0.001), effective regurgitant orifice area (p < 0.001) and regurgitant volume (p < 0.001) between baseline and hospital discharge. We also observed a significant reduction in tricuspid annulus diameter (p < 0.001), right ventricular basal diameter (p = 0.001) and right atrial area (p = 0.026). Conclusion: Treatment with the edge-to-edge TriClip device is safe and effective. The resulting echocardiographic improvements indicate tricuspid valve leaflet approximation does not just significantly reduce the grade of TR but also affects adjacent structures and improves right ventricular afterload adaptation.

Edge-to-Edge Repair for Tricuspid Valve Regurgitation. Preliminary Echo-Data and Clinical Implications from the Tricuspid Regurgitation IMAging (TRIMA) Study

Grigioni, Francesco;Ussia, Gian Paolo
2022-01-01

Abstract

: Background: The natural history of tricuspid valve regurgitation (TR) is characterized by poor prognosis and high in-hospital mortality when treated with isolated surgery. We report the preliminary echocardiographic and procedural results of a prospective cohort of symptomatic patients with high to prohibitive surgical risk and at least severe TR who underwent transcatheter edge-to-edge repair through the TriClipTM system. Methods: From June 2020 to March 2022, 27 consecutive patients were screened, and 13 underwent transcatheter TriClipTM repair. In-hospital, 30-day and six-month clinical and echocardiographic outcomes were collected. Results: Nine patients had severe, three massive and one baseline torrential TR. Sustained TR reduction of ≥1 grade was achieved in all patients, of which 90% reached a moderate TR or less. On transthoracic echocardiographic examination, there were significant reductions in vena contracta width (p < 0.001), effective regurgitant orifice area (p < 0.001) and regurgitant volume (p < 0.001) between baseline and hospital discharge. We also observed a significant reduction in tricuspid annulus diameter (p < 0.001), right ventricular basal diameter (p = 0.001) and right atrial area (p = 0.026). Conclusion: Treatment with the edge-to-edge TriClip device is safe and effective. The resulting echocardiographic improvements indicate tricuspid valve leaflet approximation does not just significantly reduce the grade of TR but also affects adjacent structures and improves right ventricular afterload adaptation.
2022
echocardiography; edge-to-edge repair; transcatheter interventions; tricuspid regurgitation; tricuspid valve
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12610/74105
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact