Purpose To evaluate overall patient satisfaction, spectacle independence, visual acuity, and prevalence of optical phenomena following bilateral implantation of a new non-diffractive extended depth-of-focus intraocular lens targeted for minimonovision. Methods Multicenter prospective case series. Postoperative far and near visual acuity at 3 months and patient quality of life by NEI-VFQ-25 questionnaire were assessed. Postoperative evaluation included defocus curves analysis, spectacle independence assessment, and recording of photic phenomena. Results The study enrolled 97 eyes of 59 patients that underwent femtosecond-assisted cataract surgery with AcrySof IQ Vivity intraocular lens implantation. Thirty subjects (60 eyes) were eligible for analysis. After 3 months, postoperative achieved binocular uncorrected visual acuity was -0.03 +/- 0.06 logarithm of the minimum angle of resolution for distance, 0.06 +/- 0.06 logarithm of the minimum angle of resolution for intermediate, and 0.19 +/- 0.03 logarithm of the minimum angle of resolution for near. Defocus curve showed a smooth profile with no abrupt decrease of visual acuity. Minimonovision significantly improved visual acuity compared to when minimonovision was neutralized, for values of defocus curves from -1 to -3 D (p < 0.05). Twenty-six (87%) patients reported complete spectacle independence. High levels of satisfaction for distance and near vision resulted at VFQ-25 questionnaire. Only two patients complained of halos (6.7%) and one of them also of glare (3.3%). Conclusions Implantation of this new non-diffractive extended depth-of-focus intraocular lens with minimonovision resulted in satisfying far, intermediate, and near visual acuity with a consistent reduction of spectacle dependence and improvement in patient's quality of life.
Effect of minimonovision in bilateral implantation of a novel non-diffractive extended depth-of-focus intraocular lens: Defocus curves, visual outcomes, and quality of life
Coassin, Marco;Di Zazzo, Antonio;Bonini, Stefano;
2022-01-01
Abstract
Purpose To evaluate overall patient satisfaction, spectacle independence, visual acuity, and prevalence of optical phenomena following bilateral implantation of a new non-diffractive extended depth-of-focus intraocular lens targeted for minimonovision. Methods Multicenter prospective case series. Postoperative far and near visual acuity at 3 months and patient quality of life by NEI-VFQ-25 questionnaire were assessed. Postoperative evaluation included defocus curves analysis, spectacle independence assessment, and recording of photic phenomena. Results The study enrolled 97 eyes of 59 patients that underwent femtosecond-assisted cataract surgery with AcrySof IQ Vivity intraocular lens implantation. Thirty subjects (60 eyes) were eligible for analysis. After 3 months, postoperative achieved binocular uncorrected visual acuity was -0.03 +/- 0.06 logarithm of the minimum angle of resolution for distance, 0.06 +/- 0.06 logarithm of the minimum angle of resolution for intermediate, and 0.19 +/- 0.03 logarithm of the minimum angle of resolution for near. Defocus curve showed a smooth profile with no abrupt decrease of visual acuity. Minimonovision significantly improved visual acuity compared to when minimonovision was neutralized, for values of defocus curves from -1 to -3 D (p < 0.05). Twenty-six (87%) patients reported complete spectacle independence. High levels of satisfaction for distance and near vision resulted at VFQ-25 questionnaire. Only two patients complained of halos (6.7%) and one of them also of glare (3.3%). Conclusions Implantation of this new non-diffractive extended depth-of-focus intraocular lens with minimonovision resulted in satisfying far, intermediate, and near visual acuity with a consistent reduction of spectacle dependence and improvement in patient's quality of life.| File | Dimensione | Formato | |
|---|---|---|---|
| 
									
										
										
										
										
											
												
												
												    
												
											
										
									
									
										
										
											20.500.12610-76025.pdf
										
																				
									
										
											 non disponibili 
											Tipologia:
											Versione Editoriale (PDF)
										 
									
									
									
									
										
											Licenza:
											
											
												Copyright dell'editore
												
												
												
											
										 
									
									
										Dimensione
										3.4 MB
									 
									
										Formato
										Adobe PDF
									 
										
										
								 | 
								3.4 MB | Adobe PDF | Visualizza/Apri Richiedi una copia | 
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


