: A trabecular metal screw has been suggested to treat avascular osteonecrosis of the femoral head. Non-surgical management with partial weight bearing can only be selected for early stages and very small lesions. Even in such cases, it has been proven to be ineffective in 80-90 % of patients. Conversely, the results with trabecular metal implants are not always clinically satisfactory, and some patients can show emerging pain and activity limitations that could require conversion to a total hip arthroplasty. Hereby we report the results of 6 patients who underwent this implant and describe the histopathology of the bone at the femoral neck and to speculate on the causes of complications encountered during arthroplasty surgery. The necrosis was stopped in 1 case, and 5 hips showed disease progression. Two protrusions of the screw apex were observed. In one case, rupture of the greater trochanter during prosthesis implant occurred. After trabecular metal implants for avascular osteonecrosis, some patients can require conversion to a total hip arthroplasty. Two patients had an intraoperative fracture with detachment of the greater trochanter that required wiring. Complications related to implant removal can be encountered, and the orthopedic surgeon should be aware of removal techniques.

Trabecular metal screw implanted for avascular necrosis of the femoral head may complicate subsequent arthroplasty surgery

Papapietro, N.;Salvatore, G.;Denaro, V.
2013-01-01

Abstract

: A trabecular metal screw has been suggested to treat avascular osteonecrosis of the femoral head. Non-surgical management with partial weight bearing can only be selected for early stages and very small lesions. Even in such cases, it has been proven to be ineffective in 80-90 % of patients. Conversely, the results with trabecular metal implants are not always clinically satisfactory, and some patients can show emerging pain and activity limitations that could require conversion to a total hip arthroplasty. Hereby we report the results of 6 patients who underwent this implant and describe the histopathology of the bone at the femoral neck and to speculate on the causes of complications encountered during arthroplasty surgery. The necrosis was stopped in 1 case, and 5 hips showed disease progression. Two protrusions of the screw apex were observed. In one case, rupture of the greater trochanter during prosthesis implant occurred. After trabecular metal implants for avascular osteonecrosis, some patients can require conversion to a total hip arthroplasty. Two patients had an intraoperative fracture with detachment of the greater trochanter that required wiring. Complications related to implant removal can be encountered, and the orthopedic surgeon should be aware of removal techniques.
File in questo prodotto:
File Dimensione Formato  
EurJOrthopSurgTraumatol_2014_931.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 769.32 kB
Formato Adobe PDF
769.32 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12610/77043
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact