Background: This study aims to assess the benefit of a deep inspiration breath hold (DIBH) over the standard irradiation technique, and eventually to identify anatomical and/or treatment preplanning characteristics correlated with the LAD dose. Methods: Patients with left-sided breast cancer undergoing whole breast radiotherapy with DIBH were analyzed. All patients included in the analysis had plans in DIBH and free-breathing (FB). Receiving operating characteristics (ROC analysis) were used to identify the cut-off point of parameters to predict the LAD maximum dose > 10 Gy and LAD mean dose > 4 Gy, and the areas under the curve (AUCs) were computed. Post-test probability has been performed to evaluate the effect of parameters’ combination. Results: One hundred ninety-seven patients were analyzed. The LAD dose was significantly reduced in DIBH plans with the maximum and mean dose reduced by 31.7% (mean value 3.5 Gy vs. 4.8 Gy, p ≤ 0.001) and 28.1% (mean value 8.2 Gy vs. 12.8 Gy, p ≤ 0.001) in DIBH plans compared to FB plans. The strongest predictor of the LAD dose (maximum > 10 Gy and mean > 4 Gy) was the minimum distance of LAD from tangent open fields. Other parameters were lung volume and heart volume (LAD Dmax > 10 Gy) and lung volume, heart volume, and breast separation (LAD Dmean > 4 Gy). Conclusion: The dosimetric advantage of DIBH is clear in all patients and DIBH should always be preferred.

Preventing Cardiotoxicity in Personalized Breast Irradiation

Ippolito E.;Greco C.;Marrocco M.;Rinaldi C. G.;Fiore M.;Trodella L. E.;Ramella S.
2023-01-01

Abstract

Background: This study aims to assess the benefit of a deep inspiration breath hold (DIBH) over the standard irradiation technique, and eventually to identify anatomical and/or treatment preplanning characteristics correlated with the LAD dose. Methods: Patients with left-sided breast cancer undergoing whole breast radiotherapy with DIBH were analyzed. All patients included in the analysis had plans in DIBH and free-breathing (FB). Receiving operating characteristics (ROC analysis) were used to identify the cut-off point of parameters to predict the LAD maximum dose > 10 Gy and LAD mean dose > 4 Gy, and the areas under the curve (AUCs) were computed. Post-test probability has been performed to evaluate the effect of parameters’ combination. Results: One hundred ninety-seven patients were analyzed. The LAD dose was significantly reduced in DIBH plans with the maximum and mean dose reduced by 31.7% (mean value 3.5 Gy vs. 4.8 Gy, p ≤ 0.001) and 28.1% (mean value 8.2 Gy vs. 12.8 Gy, p ≤ 0.001) in DIBH plans compared to FB plans. The strongest predictor of the LAD dose (maximum > 10 Gy and mean > 4 Gy) was the minimum distance of LAD from tangent open fields. Other parameters were lung volume and heart volume (LAD Dmax > 10 Gy) and lung volume, heart volume, and breast separation (LAD Dmean > 4 Gy). Conclusion: The dosimetric advantage of DIBH is clear in all patients and DIBH should always be preferred.
2023
breast cancer; breast irradiation; DIBH; left descending artery
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12610/81463
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact