Laser Ablation (LA) is a minimally-invasive procedure for tumor treatment. LA outcomes depend on the heat distribution inside tissues and require accurate temperature measurement during the procedure. Magnetic resonance imaging (MRI) allows a non-invasive and three-dimensional thermometry of the organ undergoing LA.In this study, the temperature distribution within two swine pancreases and three swine livers undergoing LA (Nd:YAG, power: 2 W, treatment time: 4 min) was monitored by a 1.5-T MR scanner, utilizing two T1-weighted sequences (IRTF and SRTF). The signal intensity in four regions of interest, placed at different distances from the laser applicator, was related to temperature variations monitored in the same regions by twelve fiber Bragg grating sensors. The relationship between the signal intensity and temperature increase was calculated to obtain the calibration curve and to evaluate accuracy, sensibility and precision of each sequence. This is the first study of MR-based thermometry during LA on pancreas. More specifically, the IRTF sequence provides the highest temperature sensitivity in both liver (1.8 ± 0.2 °C−1) and pancreas (1.8 ± 0.5 °C−1) and the lowest precision and accuracy. SRTF sequence on pancreas presents the highest accuracy and precision (MODSFRT = −0.1 °C and LOASFRT = [−2.3; 2.1] °C)

Magnetic Resonance-based thermometry during Laser Ablation on ex-vivo swine pancreas and liver

Di Matteo FM;Beomonte Zobel B;Silvestri S;Schena E
2015-01-01

Abstract

Laser Ablation (LA) is a minimally-invasive procedure for tumor treatment. LA outcomes depend on the heat distribution inside tissues and require accurate temperature measurement during the procedure. Magnetic resonance imaging (MRI) allows a non-invasive and three-dimensional thermometry of the organ undergoing LA.In this study, the temperature distribution within two swine pancreases and three swine livers undergoing LA (Nd:YAG, power: 2 W, treatment time: 4 min) was monitored by a 1.5-T MR scanner, utilizing two T1-weighted sequences (IRTF and SRTF). The signal intensity in four regions of interest, placed at different distances from the laser applicator, was related to temperature variations monitored in the same regions by twelve fiber Bragg grating sensors. The relationship between the signal intensity and temperature increase was calculated to obtain the calibration curve and to evaluate accuracy, sensibility and precision of each sequence. This is the first study of MR-based thermometry during LA on pancreas. More specifically, the IRTF sequence provides the highest temperature sensitivity in both liver (1.8 ± 0.2 °C−1) and pancreas (1.8 ± 0.5 °C−1) and the lowest precision and accuracy. SRTF sequence on pancreas presents the highest accuracy and precision (MODSFRT = −0.1 °C and LOASFRT = [−2.3; 2.1] °C)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12610/1724
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 28
social impact