This Letter reports on the testing and assessment of an optical computed tomography-navigation system for percutaneous lung interventional, SIRIO, showing how the lesion diameter affects the bioptic procedure. Clinical data, relating to 501 patients, were collected at the Department of Interventional Radiology of Policlinico Universitario Campus Bio-Medico. This Letter shows that the diameter of lesion affects only the procedure duration (50.91 +/- 18.87 min for lesions of diameter <= 20 mm and 44.98 +/- 19.43 min for lesions of diameter >20 and <= 40 mm). For the nodules with a diameter <= 20 mm, there is a significant increase in the duration of the procedure (for each mm less the time increases by 6 s). Other parameters like the mean effective radiation dose and the presence of a diagnostic or non-diagnostic specimen do not depend, instead, on the lesion size. The economic analysis based on the biopsy procedure with SIRIO shows the necessity to adopt a new reimbursement system for percutaneous biopsy performed using navigation systems to stimulate their use to get important non-economic gains such as early diagnosis, reduction of the absorbed dose of X-rays and increasing number of lung cancers in a curable early stage.

Efficacy and economic impact evaluation of a navigation system for assisted lung biopsy

Petitti T;Beomonte Zobel B;Guglielmelli E
2018-01-01

Abstract

This Letter reports on the testing and assessment of an optical computed tomography-navigation system for percutaneous lung interventional, SIRIO, showing how the lesion diameter affects the bioptic procedure. Clinical data, relating to 501 patients, were collected at the Department of Interventional Radiology of Policlinico Universitario Campus Bio-Medico. This Letter shows that the diameter of lesion affects only the procedure duration (50.91 +/- 18.87 min for lesions of diameter <= 20 mm and 44.98 +/- 19.43 min for lesions of diameter >20 and <= 40 mm). For the nodules with a diameter <= 20 mm, there is a significant increase in the duration of the procedure (for each mm less the time increases by 6 s). Other parameters like the mean effective radiation dose and the presence of a diagnostic or non-diagnostic specimen do not depend, instead, on the lesion size. The economic analysis based on the biopsy procedure with SIRIO shows the necessity to adopt a new reimbursement system for percutaneous biopsy performed using navigation systems to stimulate their use to get important non-economic gains such as early diagnosis, reduction of the absorbed dose of X-rays and increasing number of lung cancers in a curable early stage.
2018
Interventions; Tracking
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12610/4455
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact