High rejection rates in upper-limb prosthetics stem from limited usability and excessive cognitive workload (CW), as traditional electromyographic (EMG) control strategies suffer from signal variability and require continuous user effort. Vision-based semiautonomous control strategies (SCS) are proposed to combine user input with contextual information. However, these approaches often provide limited user involvement in the loop and are not broadly validated in prosthetic applications. Their performance in usability and subjective perception remains unexplored. To address these limitations, an innovative SCS is proposed that integrates EMG signals with visual perception to enhance prosthetic performance, usability, and user experience, reducing CW. The proposed SCS allows users to intentionally select a grasp via EMG signals, while computer vision refines wrist orientation and adapts the grasp to the detected object, even in complex scenarios involving multiple objects or conflicting inputs between EMG and visual context. To assess performance, the proposed SCS is compared with the traditional EMG-based control strategy. 10 able-bodied subjects participate in comparative analysis. Results show that SCS achieves a 100% success rate (97.69% for the EMG-based strategy) while reducing task completion time by up to 52.66%. Usability increases (15-point improvement in the system usability scale score), and CW decreases, evidenced by physiological and subjective measures.

Context‐Aware Semiautonomous Control for Upper‐Limb Prostheses

Stefanelli, Enrica;Billardello, Roberto;Tamantini, Christian;Zollo, Loredana;Cordella, Francesca
2026-01-01

Abstract

High rejection rates in upper-limb prosthetics stem from limited usability and excessive cognitive workload (CW), as traditional electromyographic (EMG) control strategies suffer from signal variability and require continuous user effort. Vision-based semiautonomous control strategies (SCS) are proposed to combine user input with contextual information. However, these approaches often provide limited user involvement in the loop and are not broadly validated in prosthetic applications. Their performance in usability and subjective perception remains unexplored. To address these limitations, an innovative SCS is proposed that integrates EMG signals with visual perception to enhance prosthetic performance, usability, and user experience, reducing CW. The proposed SCS allows users to intentionally select a grasp via EMG signals, while computer vision refines wrist orientation and adapts the grasp to the detected object, even in complex scenarios involving multiple objects or conflicting inputs between EMG and visual context. To assess performance, the proposed SCS is compared with the traditional EMG-based control strategy. 10 able-bodied subjects participate in comparative analysis. Results show that SCS achieves a 100% success rate (97.69% for the EMG-based strategy) while reducing task completion time by up to 52.66%. Usability increases (15-point improvement in the system usability scale score), and CW decreases, evidenced by physiological and subjective measures.
2026
computer vision; electromyographic; pattern recognition; semiautonomous control; upper-limb prosthetics
File in questo prodotto:
File Dimensione Formato  
Advanced Intelligent Systems - 2026 - Cirelli - Context‐Aware Semiautonomous Control for Upper‐Limb Prostheses.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.66 MB
Formato Adobe PDF
1.66 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.